Home > Http Error > 12002 Error Ajax

12002 Error Ajax

Contents

The file name is a device or contains invalid characters | IE script warning: If continues to run, your computer may become unresponsive. >> IE Javascript timeout error: 12002 Filed under Regards, Ivan Danchev Telerik Do you want to have your say when we set our development plans? Progress, Telerik, and certain product names used herein are trademarks or registered trademarks of Progress Software Corporation and/or one of its subsidiaries or affiliates in the U.S. I got a similar error after it reached about 15%. Check This Out

Last edited by dglienna; September 8th, 2007 at 05:27 PM. For more information, see the specific function. Comments (1) - 4/19/2012 11:20:58 AM # Thank you very much!! It usually takes hours to appear, not 60 minutes, though.

Http Error 12002

How does Globalscape manage quality in their products? Adam 177 posts Member since: Oct 2012 Posted 25 Oct 2010 Link to this post Any additional ideas? When you Execute a command, it will now TIME OUT after 30 seconds. To start viewing messages, select the forum that you want to visit from the selection below.

For example, WinHTTP version 5.1 does not support SSL2 unless the client specifically enables it. ERROR_WINHTTP_HEADER_ALREADY_EXISTS 12155 Obsolete; no longer used. ERROR_WINHTTP_HEADER_COUNT_EXCEEDED 12181 Returned by WinHttpReceiveResponse when a larger If it is left open for X amount of time and it normally takes Y amount of time, then they cancel it with the abort9) method. Any pointers on how to get/set X? Http Error 12152 A new request handle must be created before retrying the function that originally produced this error. ERROR_WINHTTP_NAME_NOT_RESOLVED 12007 The server name cannot be resolved. ERROR_WINHTTP_NOT_INITIALIZED 12172 Obsolete; no longer

Header:  Declared in Winerror.h ERROR_INSUFFICIENT_BUFFER The size, in bytes, of the buffer supplied to a function was insufficient to contain the returned data. Wininet Error Codes In this case, the application specifies the WINHTTP_NO_CLIENT_CERT_CONTEXT macro in the lpBuffer parameter of WinHttpSetOption. Was Gandalf "meant" to confront the Balrog? Eric Prakas Subed Greenhorn Posts: 20 posted 10 years ago I can get the Y; that's 1000 ms as set on above code.

Header:  Declared in Winerror.h ERROR_NOT_SUPPORTED The required protocol stack is not loaded and the application cannot start WinSock. 12019 Error_internet_incorrect_handle_state Apparently IE7 imposes some kind of 30 second timeout. Error values whose names begin with "ERROR_WINHTTP_" are specific to the WinHTTP functions. Is there any solutions to keep the communication alive between the server and the client.

Wininet Error Codes

David CodeGuru Article: Bound Controls are Evil-VB6 2013 Samples: MS CODE Samples CodeGuru Reviewer 2006 Dell CSP 2006, 2007 & 2008 MVP Visual Basic If your question has been answered Get More Info Options Print Article Export As PDF Find Similar Error 12002 Customer Support Software By InstantKB 2016-3 Final Execution: 0.000. 5 queries. Http Error 12002 I couldn't find anywhere that it was set, though. 12002 Error_internet_timeout On our test system, I can sometimes get 1-2% before it stops.

Do you have any RadWindows on your page that perform AJAX requests? his comment is here For example, the server referenced by the PAC URL may not have been reachable, or the server returned a 404 NOT FOUND response. ERROR_WINHTTP_UNHANDLED_SCRIPT_TYPE 12176 The script type is not Header Winhttp.h See also WinHTTP Versions     Show: Inherited Protected Print Export (0) Print Export (0) Share IN THIS ARTICLE Is this page helpful? Genady Sergeev Admin 1593 posts Posted 26 Oct 2010 Link to this post Hello Adam, After some digging it turned out that this error happens because if IE limit of 2 Error Code 12019

Next Comments require login or registration. It's strange... The time now is 01:45 PM. this contact form Explore the Telerik Feedback Portal and vote to affect the priority of the items Dan 70 posts Member since: Mar 2007 Posted 03 Aug 2015 in reply to Ivan Danchev Link

Reply With Quote 11-13-2007,08:19 AM #2 toicontien View Profile View Forum Posts er, I mean toicantien Join Date Feb 2003 Location Michigan, USA Posts 5,774 Instead of having an AJAX function Error_winhttp_timeout We found it by accident. Header:  Declared in Winerror.h ERROR_NO_MORE_FILES No more files have been found.

Windows Server 2003 with SP1 and Windows XP with SP2:  This error is not supported. ERROR_WINHTTP_CLIENT_CERT_NO_PRIVATE_KEY The context for the SSL client certificate does not have a private key associated with it.

This would help us check whether the handlers are correctly registered and we can test your configuration to see whether the issue can be reproduced at our end. error.jpg Genady Sergeev Admin 1593 posts Posted 02 Nov 2010 Link to this post Hello Adam, Is it possible to record a fiddler cap log of your session monitoring the time and/or other countries. Http Error 12029 Forum New Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders What's New?

share|improve this answer answered Feb 8 '13 at 20:44 Jack 1,2441716 add a comment| Your Answer draft saved draft discarded Sign up or log in Sign up using Google Sign Well, I'd bet that they don't work anymore, either. For more information, see the WINHTTP_OPTION_CLIENT_CERT_CONTEXT option.Windows Server 2003 with SP1 and Windows XP with SP2:  This error is not supported. ERROR_WINHTTP_CLIENT_CERT_NO_ACCESS_PRIVATE_KEY The application does not have the required privileges to access the navigate here Reply With Quote September 11th, 2007,11:59 AM #24 dglienna View Profile View Forum Posts Visit Homepage ex MVP - Visual Basic Power Poster Join Date Jan 2006 Location Fox Lake, IL

Is there another place I can drop the file for you? Compute the Mertens function Rewards System: Points or $? Sales: 1.800.290.5054 - 1.210.308.8267 Support: 1.210.366.3993 Contact Us Copyright ©1996-2016 GlobalSCAPE, Inc. Reply With Quote September 11th, 2007,12:19 PM #26 dglienna View Profile View Forum Posts Visit Homepage ex MVP - Visual Basic Power Poster Join Date Jan 2006 Location Fox Lake, IL

The client certificate may have been imported to the computer without the private key. Reply With Quote September 21st, 2010,09:34 AM #29 navyjax2 View Profile View Forum Posts Junior Member Join Date Apr 2008 Posts 1 Re: [RESOLVED] 12002 - Timeout Error What it seems For more information, see the WINHTTP_OPTION_CLIENT_CERT_ISSUER_LIST option. I have do a lot of research for this problem, thank you!!!

I'm going to make a support call on Monday, but I thought I'd post it here. You can learn more about execution timeout here. The context is I'm refreshing few user controls on the page - RadWindow - at 1 minute interval, using RadAjaxPanel. I have tried changing the connection request header from ajax to "close","open","keep-alive" nothing works.

msinet.ocx The problem was caused by an upgrade to IE7. somtimes within 20 minutes of accessing the JSP; sometimes 10 minutes. The Inet1.State that gets returned is 12002 - Timeout David CodeGuru Article: Bound Controls are Evil-VB6 2013 Samples: MS CODE Samples CodeGuru Reviewer 2006 Dell CSP 2006, 2007 & 2008 MVP The day after running his laptop on my wifi succcessfully, he upgraded to IE7, and it quit working immediately.

WinInet provides stand-alone applications with easy access to standard Internet protocols such as Gopher, FTP, and HTTP. All Rights Reserved. Forum New Posts FAQ Calendar Forum Actions Mark Forums Read Quick Links Today's Posts View Site Leaders What's New? radupload.jpg Adam 177 posts Member since: Oct 2012 Posted 18 Oct 2010 Link to this post Some additional information.

Windows Server 2003 with SP1 and Windows XP with SP2:  This error is not supported. ERROR_WINHTTP_CONNECTION_ERROR 12030 The connection with the server has been reset or terminated, or an incompatible SSL protocol was All rights reserved.Privacy Policy Enter Email Address...